• s_banner

OEM manufacturer Dual Energy X Ray Absorptiometry Test - Ultrasonic Bone Densitometer BMD-A7 New – Pinyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Innovation, excellent and reliability are the core values of our business. These principles today extra than ever form the basis of our success as an internationally active mid-size company for Dual Energy X Ray Absorptiometry, Dual Energy X Ray Absorptiometry Whole Body, Bone Densitometry Cost, To improved expand market, we sincerely invite ambitious individuals and providers to hitch as an agent.
OEM manufacturer Dual Energy X Ray Absorptiometry Test - Ultrasonic Bone Densitometer BMD-A7 New – Pinyuan Detail:

bone densitometer machine is to measure the bone density or bone strength of the People’s radius and tibia. It is for preventing osteoporosis.

It is an economic solution for evaluating the risk of osteoporotic fracture. Its high accuracy assists in the first diagnosis of osteoporosis monitoring bone changes. It provides fast, convenient and easy-to-use informations on bone quality and fracture risk.

Application Range

Our Ultrasound Bone Densitometry always used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory, Pharmacy and Health Care Products Promotion.

The Department of the General Hospital, Such as Pediatric Department, Gynecology and Obstetrics Department.

A7-(2)

Performance Parameter

1. Measurement parts: radius and Tibia.

2. Measurement mode: double emission and double receiving.

3. Measurement parameters: Speed of sound (SOS).

4. Analysis Data: T- Score, Z-Score, Age percent[%], Adult percent[%], BQI (Bone quality Index ), PAB[Year] (physiological age of bone), EOA[Year] (Expected Osteoporosis age), RRF(Relative Fracture Risk).

5. Measurement Accuracy : ≤0.15%.

6. Measurement Reproducibility: ≤0.15%.

7. Measurement time: Three-cycles adult measurement.

8. Probe frequency : 1.20MHz.

9. Date analysis : it adopt a special intelligent real –time data analysis system, it selects the adult or child databases according to the age automatically.

10. Temperature control: Perspex sample with temperature instructions.

11. All the people of the world. It measuring the people between the age Of 0 and 100,(Children: 0-12 years old, Teenagers: 12-20 years old, Adults:20-80 years old, The Elderly 80-100 yeas old, only need to input the age and recognizing automatically.

12. Temperature display calibration block: the calibration with pure copper and Perspex, the calibrator display current temperature and standard SOS. The equipment leave the factory with Perspex sample.

13. repot mode: color.

14. Report format: supply A4, 16K ,B5 and more size report.

15. Bone densitometer main unit: Drawing Aluminum mould manufacturing, it is exquisite and beautiful.

16. With HIS , DICOM, database connectors.

17. Bone densitometer probe connector: multipoint access mode with high shield and mold manufacturing, to ensure the lossless transmission of the ultrasonic signals.

18. Computer Main Unit: the original Dell Rack business Computer. Signal processing and analysis are fast and accurate.

19. Computer configuration: original Dell business configuration: G3240, dual core, 4G memory, 500G hard disk, original Dell recorder., wireless mouse. (optional ).

20. Computer Monitor: 20’ color HD color LED monitor. (optional ).

21. Fluid Protection: main unit waterproof level IPX0, probe waterproof level IPX7.

Configuration

1. Ultrasound Bone Densitometer Trolley Main unit (inner Dell business Computer with i3 CPU )

2. 1.20MHz Probe

3. BMD-A5 Intelligent Analysis System

4.Canon Color InkJet Printer G1800

5. Dell 19.5 inch Color LED Mornitor

6. Calibrating Module( Perspex sample)

7. Disinfectant Coupling Agent

Package Size

One Carton

Size(cm): 59cm×43cm×39cm

G.W.12 Kgs

N.W: 10 Kgs

One Wooden Case

Size(cm): 73cm×62cm×98cm

G.W.48 Kgs

N.W: 40 Kgs

Osteoporosis Risk Factors

There are a number of factors that can increase someone’s risk of developing osteoporosis. Some can be influenced, whereas others cannot. The main risk factors for osteoporosis include:

Age: As we get older, our bone density decreases and the risk of developing osteoporosis increases. Men over the age of 65 and post-menopausal women are at the greatest risk.

Sex: Women develop osteoporosis more often than men, and they are also more likely to have bone fractures.

Low body weight (compared to body size)

Diet low in calcium

Vitamin D deficiency

Lack of exercise

Family history: Women whose mother or father broke their hip because of osteoporosis are at greater risk of developing osteoporosis themselves.

Smoking

Drinking a lot of alcohol

Long-term steroid use

Use of other medications, such as some antidepressants (SSRIs) or diabetes medicines (glitazones)

Conditions such as rheumatoid arthritis or hyperthyroidism (an overactive thyroid gland)

Our BMD-A7 Is Very Popular

image1
image3
image2
image4

Bone Density Testing Results Will Be In The Form Of Two Scores

T score: This compares your bone density with a healthy, young adult of your gender. The score indicates if your bone density is normal, below normal, or at the levels that indicate osteoporosis.
Here’s what the T score means:
● -1 and above: Your bone density is normal
● -1 to -2.5: Your bone density is low, and it may lead to osteoporosis
● -2.5 and above: You have osteoporosis

Z score: This allows you to compare how much bone mass you have compared with other people of your age, gender, and size.
A Z score below -2.0 means that you have less bone mass than someone your age and that it could be caused by something other than aging.


Product detail pictures:

OEM manufacturer Dual Energy X Ray Absorptiometry Test - Ultrasonic Bone Densitometer BMD-A7 New – Pinyuan detail pictures

OEM manufacturer Dual Energy X Ray Absorptiometry Test - Ultrasonic Bone Densitometer BMD-A7 New – Pinyuan detail pictures

OEM manufacturer Dual Energy X Ray Absorptiometry Test - Ultrasonic Bone Densitometer BMD-A7 New – Pinyuan detail pictures

OEM manufacturer Dual Energy X Ray Absorptiometry Test - Ultrasonic Bone Densitometer BMD-A7 New – Pinyuan detail pictures

OEM manufacturer Dual Energy X Ray Absorptiometry Test - Ultrasonic Bone Densitometer BMD-A7 New – Pinyuan detail pictures


Related Product Guide:

Our target is always to satisfy our customers by offering golden support, superior value and high quality for OEM manufacturer Dual Energy X Ray Absorptiometry Test - Ultrasonic Bone Densitometer BMD-A7 New – Pinyuan , The product will supply to all over the world, such as: Angola, Greenland, Tajikistan, we are fully determined to control the whole supply chain so as to provide quality products at competitive price in a timely manner. We are keeping up with the advanced techniques, growing through creating more values for our clients and society.
  • The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Kay from Dominica - 2018.06.18 17:25
    The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Roland Jacka from Japan - 2018.07.26 16:51