We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Bone Densitometry Equipment Manufacturers, Bone Densitometry Brands, Bone mineral density analyzer, All the time, we have been paying attention on all details to insure each product satisfied by our customers.
Quality Inspection for Bone Densitometer Forearm - BMD-A3 Basic ultrasound bone densitometer for bone density testing – Pinyuan Detail:

8
9
10

Features

Safe for the measurement of younger or pregnant person, with non-invasive nature of ultrasound

11

Convenient measuring parts: 1/3 of Radius and Middle of Tibia  

12
13

Approx. 3 seconds per measurement, suitable for screening test for osteoporosis

14

Main Function of the portable ultrasound Bone Densitometry is to measure the bone density or bone strength of the People’s radius and tibia. It is for Preventing osteoporosis.

It is an economic solution for evaluating the risk of osteoporotic fracture. Its high accuracy assists in the first diagnosis of osteoporosis monitoring bone changes. It provides fast, convenient and easy-to-use informations on bone quality and fracture risk.

this model is very easy to carry , this model was choose by GSK, Roche Group,999 Group, Wyeth and Amyway and yangshengtang , Byhealth, Renhe, some other pharmaceutical company, they use this do bone density testing, to promote their medicine

Application:

Our BMD have extensive application: it used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory, Pharmacy and Health Care Products
The Department of the General Hospital, Such as Pediatric Department, Gynecology and Obstetrics Department, Orthopedics Department, Geriatrics Department, Physical Examination, Department, Rehabilitation Department

Performance parameter:

1.Measurement parts: radius and Tibia
2. Measurement mode: double emission and double receiving
3.Measurement parameters: Speed of sound (SOS)
4.Analysis Data: T- Score, Z-Score, Age percent[, Adultt percent[, BQI (Bone quality Index ), PAB[Year] (physiological age of bone), EOA[Year] (Expected Osteoporosis age), RRF(Relative Fracture Risk). BMI , SOS
5.Measurement Accuracy : ≤0.25%

6.Measurement Reproducibility: ≤0.25%
7.Measurement time:
Three Cycles adults measuring time Three Cycle Children measuring time < 3seconds
8.Probe frequency : 1.20MHz
9. CE , ROHS, LVD , ISO , CFDA, CFS


Product detail pictures:

Quality Inspection for Bone Densitometer Forearm - BMD-A3 Basic ultrasound bone densitometer for bone density testing – Pinyuan detail pictures

Quality Inspection for Bone Densitometer Forearm - BMD-A3 Basic ultrasound bone densitometer for bone density testing – Pinyuan detail pictures


Related Product Guide:

Our business has been focusing on brand strategy. Customers' pleasure is our best advertising. We also offer OEM company for Quality Inspection for Bone Densitometer Forearm - BMD-A3 Basic ultrasound bone densitometer for bone density testing – Pinyuan , The product will supply to all over the world, such as: Peru, Estonia, Surabaya, In the future, we promise to keep offer the high quality and more cost-effective products, the more efficient after sales service to our all customers all over the world for the common development and the higher benefit.
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Elsa from Nepal - 2017.06.16 18:23
    The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Alice from Oslo - 2017.09.29 11:19