• s_banner

Arteriosclerosis detector: Multi-department scenario adaptation and the clinical value realization of “simple, fast, accurate and stable”

1. The Clinical Necessity of Arteriosclerosis Detection: The Core Value of Professional Equipment in Departments

 

Arteriosclerosis is an important cause of major diseases such as cardiovascular diseases, stroke and peripheral vascular diseases. Its early symptoms are insidious and may lead to serious adverse events after progression. The “China Cardiovascular Health and Disease Report 2023″ shows that the prevalence of arteriosclerosis among people over 40 years old in China exceeds 40%, and it is showing a trend of younger age. For medical institutions, professional arteriosclerosis detectors are a key support for achieving the full-process management of “early screening, precise diagnosis, and dynamic monitoring” of the disease. They can enhance the scientificity and efficiency of clinical decision-making and provide patients with more targeted intervention plans.

 

2. Analysis of the Multi-Departmental Application Scenarios of Pinyuan Arteriosclerosis Detector

 

The Pinyuan Arteriosclerosis detector features “precise measurement, comprehensive analysis, and convenient operation” as its core characteristics, and is suitable for the clinical needs of multiple departments. Its specific applications are as follows:

 

Cardiovascular Department: The core tool for the diagnosis and treatment of vascular diseases

 

The cardiovascular department often deals with conditions directly related to vascular lesions such as coronary heart disease and peripheral artery disease, and requires rapid and accurate assessment of vascular function. The Pinyuan arteriosclerosis detector supports dual index measurement of pulse wave velocity (PWV) and ankle-brachial index (ABI). Among them, the PWV value can reflect the elastic state of the artery, and the ABI indicates lower extremity vascular blockage.

图片5

Neurology: An important support for the prevention and control of stroke risk

 

Carotid and intracranial atherosclerosis is one of the main causes of stroke. The neurology department needs to have a comprehensive understanding of the patient’s vascular condition to predict the risk. The comprehensive analysis function of the Pinyuan Arteriosclerosis detector can provide a “full-dimensional vascular portrait”, assess carotid artery elasticity through PWV, and determine the degree of systemic vascular hardening in combination with ABI, providing data support for stroke risk assessment. For high-risk groups such as those with hypertension and hyperlipidemia, the equipment can serve as a regular monitoring tool to promptly warn of the progression of vascular lesions and assist doctors in adjusting intervention strategies.

 

Endocrinology Department: Practical AIDS for the Management of Diabetic Complications

 

Diabetic patients with long-term high blood sugar are prone to damage the vascular endothelium and belong to a high-risk group for arteriosclerosis. The endocrinology department needs high-frequency and convenient detection tools for long-term management. The operation of the Pinyuan arteriosclerosis detector is standardized. It can simultaneously apply pressure to the limbs and quickly generate color dynamic report forms containing waveforms and parameters, meeting the departmental requirements of “high-frequency detection and batch processing”.

 

Geriatrics Department: Long-term monitoring program for vascular health of the elderly population

 

The elderly are a high-risk group for arteriosclerosis and often have underlying diseases such as hypertension and diabetes, requiring long-term monitoring of their vascular conditions. The report of Pinyuan Arteriosclerosis detector includes risks and suggestions, which is convenient for doctors to have a direct understanding of the patient’s vascular condition.

 

Physical Examination Center: An efficient and suitable project for health screening

 

The physical examination center needs to meet the demands of large-scale population screening, and thus has high requirements for the efficiency, standardization and ease of interpretation of the testing tools. Arteriosclerosis detection can serve as a core item in cardiovascular and cerebrovascular risk screening, helping examinees identify potential vascular problems at an early stage and enhancing the practicality and value of physical examination services.

图片6

3. The core advantage of multi-department compatibility of Pin Yuan Equipment

 

The multi-departmental adaptability of the Pinyuan Arteriosclerosis detector stems from its clinical need-oriented design, which focuses on the key aspects of “simple operation, fast detection speed, high accuracy, and good repeatability”.

 

Simple operation: The equipment interface is simple and the operation process is standardized. Medical staff can operate independently after a short period of training, significantly reducing the learning and usage costs of the department and meeting the different operation needs of medical staff in various departments.

 

Fast detection speed: Short single detection time, capable of quickly completing the test and generating a report, efficiently meeting the demands of scenarios such as emergency assessment in cardiovascular departments, batch testing in endocrinology departments, and large-scale screening in physical examination centers.

 

High accuracy: Professional technology is adopted to ensure the detection accuracy. The PWV and ABI detection data are accurate and meet the relevant clinical diagnosis standards, providing reliable data support for the diagnosis and treatment and risk assessment of various departments.

 

Good repeatability: The detection performance is stable, and the consistency of multiple test results is high, meeting the scenarios with high requirements for the stability of test results such as long-term monitoring and continuous assessment in various departments, while reducing the risk of data error.

 

4, precisely match demands and empower clinical diagnosis and treatment

 

The core value of arteriosclerosis detection lies in “early detection and early intervention”, which requires the equipment to have the core capabilities of being precise, convenient and suitable for clinical scenarios. Pinyuan Medical has been deeply engaged in the fields of bone health and vascular detection. Its arteriosclerosis detector has passed relevant certifications such as ISO9001 and CE, and it has a full-chain quality control system. For medical institutions with equipment procurement needs, the multi-departmental adaptability and clinical practical value of the Pinyuan arteriosclerosis detector can effectively address the pain point of “mismatch between equipment and departmental demands”. If you need to know the details of equipment application or matters related to cooperation, you can further communicate and consult with Pinyuan Medical.


Post time: Nov-13-2025