• s_banner

2022 High quality Whole Body Bone Densitometry - DEXA Bone Densitometry DXA 800E – Pinyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our team through qualified training. Skilled professional knowledge, powerful sense of support, to satisfy the support desires of consumers for Bone Densitometer Quotation, Bone Densitometry Report Sample, bone loss, All prices depend upon the quantity of your order; the more you order, the more economical the price is. We also offer good OEM service to many famous brands.
2022 High quality Whole Body Bone Densitometry - DEXA Bone Densitometry DXA 800E – Pinyuan Detail:

Application

Dual-Energy X-ray Absorptiometry (DXA or DEXA) using a very small dose of ionizing radiation to produce pictures of the inside of the forearm to measure bone density . It is evaluating for Osteoporosis and Osteopenia and provides a versatile solution for evaluating the risk of osteoporotic fracture.

It is an enhanced form of X-ray technology that is used to measure bone loss. DXA is today’s established standard for measuring bone mineral density (BMD).

Measuring--the-Front-of-Forearm-

Features

Using digital Laser Beam Positioning Technique.

Special Analysis System Based on Different Countries People.

Using the Most Advanced Cone – Beam and Surface Imaging Technology.

Measurement Parts: the Front of Forearm.

With High Measurement Speed and Short Measurement Time.

Adopting the Full Closed Lead Protective Window to Measure.

Details Display

800F-English-4

Protecting Mask

800F-English-5

Using digital Laser Beam Positioning Technique

Technical Specifications

Large Scale Integrated Circuit.

Multi -Layer Circuit Board Design.

Light Source Technology With High Frequency and Small Focus.

Imported High Sensitivity Digital Camera.

Using the Cone – Beam and Surface Imaging Technology.

Using Laser Beam Positioning Technique.

Using the Unique Algorithms.

ABS Mould Manufactured, Beautiful, Strong and Practical.

Special Analysis System Based on Different Countries People.

Technical Parameter

1.Using the Dual Energy X-ray Absorptimetry.

2.Using the Most Advanced Cone – Beam and Surface Imaging Technology.

3.With High Measurement Speed and Short Measurement Time.

4.With Dual Imaging Technology to Get More Accurate Measurement.

5.Using Laser Beam Positioning Technique, Making the Measuring Position More Accurate.

6.Dectcing Image Digitization, to Get Accurate Measurement Results.

7.Adopting the Surface Imaging Technology, Measuring Faster and Better.

8.Using the Unique Algorithms to Get More Accurate Measurement Results.

9.Adopting the Full Closed Lead Protective Window to Measure, only Need to Put the Patient’s Arm into the Window. The Equipment is Indirect Contact with the Scanning Parts of the Patient. Easy to Operate for the Doctor. It is Safety for the Patient and Doctor.

10.Adopting Integrated Structure Design.

11.Unique Shape, Beautiful Appearance and Easy to Use.

Performance Parameter

1.Measurement Parts: the Front of Forearm.

2. X ray tube voltage: High Energy 70 Kv, Low Energy 45Kv.

3.The high and low energy corresponds to the current, 0.25 mA at high energy and 0.45mA at low energy.

4.X-Ray Detector: Imported High Sensitivity Digital Camera.

5.X-Ray Source: Stationary Anode X-ray Tube (with High Frequency and Small Focus).

6.Imaging Way: Cone – Beam  and Surface Imaging Technology.

7.Imaging Time: ≤ 4 Seconds.

8.Accuracy(error)≤ 0.4%.

9.Repeatability Coefficient of Variation CV≤0.25%.

10.Measuring Area :≧150mm*110mm.

11.Can be connected to hospital HIS system, PACS system.

12.Provide Worklist Port with independent upload and download function.

13.Measuring Parameter: T- Score, Z-Score, BMD, BMC, Area, Adult percent[%], Age percent[%], BQI (The Bone Quality Index) ,BMI、RRF: Relative Fracture Risk.

14. It with multi race clinical database, including: European, American, Asian, Chinese, WHO international compatibility. It measuring the people between the age of 0 and 130.

15.Measuring children over three years older.

16.Original Dell Business Computer: Intel i5, Quad Core Processor 8G 1T 22’inch HD Monitor.

17.Operation System: Win7 32-bit / 64 bit ,Win10 64 bit compatible.

18.Working Voltage: 220V±10%, 50Hz.

Who Should Get Bone Density Tested

Anyone can get osteoporosis. It’s more common among older women, but men can have it, too. Your chances increase as you age.
● You should discuss with your doctor whether you need the DXA Bone Test. They may recommend it if you meet any of the following:You’re a woman 65 or older.
● You’re a postmenopausal woman 50 or older.
● You’re a woman at the age of menopause and have a high chance for breaking bones.
● You’re a woman who has already been through menopause, younger than 65, and have other things that give you a higher chance of osteoporosis.
● You’re a man 50 or older with other risk factors.
● You break a bone after 50.
● You’ve lost more than 1.5 inches of your adult height.
● Your posture has gotten more hunched.
● You’re having back pain without any cause.
● Your periods have stopped or are irregular although you’re neither pregnant nor menopausal.
● You’ve gotten an organ transplant.
● You’ve had a drop in hormone levels.

Some types of prescription drugs can cause bone loss. These would include glucocorticoids, a class of drugs used to reduce inflammation. Tell your doctor if you’ve been on cortisone (Cortone Acetate), dexamethasone (Baycadron, Maxidex, Ozurdex), or prednisone (Deltasone).

Our DXA Bone Densitometry is  for the Peripheral testThis measures bone density at your the front of forearm.  It is usually cheaper.

Peripheral tests are also a way to screen people, so those who show a greater chance for osteoporosis can get more testing. They are also used for larger people who cannot get the central DXA because of weight limits.

The results on the bone density report
T score: This compares your bone density with a healthy, young adult of your gender. The score indicates if your bone density is normal, below normal, or at the levels that indicate osteoporosis.

Here’s what the T score means:
● -1 and above: Your bone density is normal.
● -1 to -2.5: Your bone density is low, and it may lead to osteoporosis.
● -2.5 and above: You have osteoporosis.

Z score: This allows you to compare how much bone mass you have compared with other people of your age, gender, and size.


Product detail pictures:

2022 High quality Whole Body Bone Densitometry - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures

2022 High quality Whole Body Bone Densitometry - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures

2022 High quality Whole Body Bone Densitometry - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures

2022 High quality Whole Body Bone Densitometry - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures

2022 High quality Whole Body Bone Densitometry - DEXA Bone Densitometry DXA 800E – Pinyuan detail pictures


Related Product Guide:

With sophisticated technologies and facilities, strict top quality handle, reasonable value, exceptional support and close co-operation with clients, we are devoted to furnishing the ideal worth for our clients for 2022 High quality Whole Body Bone Densitometry - DEXA Bone Densitometry DXA 800E – Pinyuan , The product will supply to all over the world, such as: Orlando, Denver, Algeria, Immediate and expert after-sale service supplied by our consultant group has happy our buyers. Comprehensive Info and parameters from the merchandise will probably be sent to you for any comprehensive acknowledge. Free samples may be delivered and company check out to our corporation. n Morocco for negotiation is constantly welcome. Hope to get inquiries type you and construct a long-term co-operation partnership.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Caroline from Borussia Dortmund - 2017.03.07 13:42
    Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Sally from Dubai - 2017.03.07 13:42